Hy-Pro vs. Brand X Filters in a Single-Pass Fluid Transfer

Posted by Jim Harlan on Tue, Feb. 07, 2017

The Problem

Today’s oil suppliers are often required to provide fluid at or below a specified ISO Cleanliness Code. One such supplier was experiencing short filter element life (15 days) on the system (7 element multi-round housing) used to achieve the required ISO Cleanliness Code of 18/16/13 in a single pass as 15W-40 oil is transferred from their bulk storage tanks to tanker trucks for delivery.

Read More

Topics: ISO 4406, filtration, breathers, offline filtration, case study, fluid transfer, DFE

High Surface Finish Defects at an Automotive Stamping Plant

Posted by Jim Harlan on Tue, Jan. 03, 2017

The Application

An automotive stamping plant operating large presses to produce body panels was experiencing high surface finish defect scrap. Lubricating oil contamination was causing surface imperfections that would be visible after painting.

The Problem

The uncoiler/washer lube oil system was protected by an off-line filtration system fitted with CJC stacked disc cellulose media filter inserts (elements). Oil analysis revealed an operating ISO code of 23/19/11. Patch analysis showed cellulose fibers were shedding into the oil from the filter inserts downstream of the filtration system.

Read More

Topics: ISO 4406, offline filtration, case study, fluid transfer, filters, DFE

  